No Hot Water: The Causes Worth Checking First
Working through no hot water by fuel type and symptom, from a pilot that will not stay lit to an element that has failed, and what is safe to check yourself.
No hot water is a symptom with a short list of causes, and the list depends on the fuel and on whether the failure is total or partial.
Gas units
The pilot will not stay lit. The thermocouple or flame sensor has failed, or the pilot orifice is dirty. This is the most common gas no-hot-water call, and it is a part.
The burner does not come on though the pilot is lit. The thermostat or gas control valve is the suspect. The water stays cold because the burner never fires.
The pilot lights and the burner fires briefly, then stops. A flame sensor, a venting fault, or a gas supply problem. Each needs a different check, and a venting fault is a safety issue rather than an inconvenience.
Nothing happens at all. Confirm the gas valve is on and the unit has power if it uses electronic ignition.
Electric units
A tripped breaker. Check the panel once. A breaker that trips again is reporting a fault, usually an element that has grounded or wiring damaged by heat or moisture.
A failed upper element. Most electric tanks have two elements. The upper one heats the top of the tank and controls the thermostat, so when it fails the water can be lukewarm rather than cold.
A tripped high-limit switch. A safety device has opened, which means the tank overheated. Resetting it without finding out why is the mistake that leads to a repeat.
Failed wiring at the element. Heat and age take a toll on the connections, and a loose connection can fail without tripping anything.
Both fuel types
A broken dip tube. Cold water enters at the top and should travel to the bottom through a tube. When the tube breaks, cold water short-circuits to the outlet, so hot water runs out almost immediately.
A shut valve. A valve closed during other work, a shared supply, or a fixture issue elsewhere.
A recirculation fault. On systems with a loop, a failed pump or a control problem can leave hot water sitting where it is not needed.
Tankless units
A flow rate below the activation threshold. The unit does not fire for a trickle. This is normal behaviour, not a fault.
Scale. Reduced output and error codes at high flow, especially in hard water.
A blocked condensate line, a dirty inlet filter or a failed flow sensor. All produce no-hot-water symptoms that look identical from the tap.
What is safe to check
The gas valve position, the breaker once, the pilot according to the label, whether other fixtures in the building have hot water, and whether the unit has power. Beyond that, the diagnosis needs a meter and access to components.
The call threshold
A pilot that will not stay lit, a breaker that trips again, water anywhere near the unit, a gas smell, or a tankless unit showing an error code. Those are the point at which the phone is more useful than the checklist. The repair page covers what each fix involves, and the emergency page covers the hazards.