A tankless heater heats water as it flows rather than storing it hot. That single difference ripples through sizing, venting, gas supply, maintenance and price, and it is why a tankless conversion is closer to a new installation than to a swap.
How the unit works
Cold water passes through a heat exchanger fired by gas or heated by electric elements. Output is rated by flow at a given temperature rise: the colder the incoming water and the higher the target temperature, the lower the flow the unit can sustain. Two showers running together is a flow question, not a tank-size question.
Sizing by flow, not by gallons
Storage tanks get compared by volume; tankless units get compared by capacity. The useful inputs are the number of outlets likely to run at once, their flow rates, and the incoming water temperature in the coldest months.
An undersized unit shows its limits as temperature swings when a second tap opens, or as water that never reaches the setpoint in winter. An oversized unit costs more and may not modulate well.
Venting, gas and condensate
Tankless venting is model-specific: Category III stainless for many non-condensing units, Category IV PVC or CPVC for condensing models, with maximum lengths and termination rules set by the manufacturer. The vent cannot simply reuse the old tank's flue.
Gas supply is the other common constraint. A tankless burner can demand more than the line that fed a tank, so the line may need upsizing. On the electric side, the panel capacity is the equivalent question.
Condensing units produce acidic condensate that must be drained or neutralised according to the installation instructions. It is a small detail that is easy to omit and expensive to retrofit.
Scale and maintenance
The heat exchanger is the part that fails or loses performance. Scale insulates it, reduces output and eventually blocks flow. Descaling on a schedule is the tankless version of flushing a tank, and it matters more in hard water.
Where the cost sits
Tankless equipment costs more than a storage tank, and the installation tends to involve more: venting, gas work, sometimes electrical work and condensate. The running-cost benefit comes from avoiding standby losses, so a household that uses hot water in short bursts sees less of it than one with steady demand.
The installation page covers the general conditions, and replacement covers the decision to change type. Coverage runs across the fourteen places this site serves.