At 2,750 feet, a tankless unit is a bet on the space it hangs in. Get that right and it is efficient and compact; get it wrong and one cold night ends it.
The bet
After a tap closes, water stays in the coil. A unit on a wall that faces the weather, or in a tack room that is not heated, will freeze it. A split coil is a replacement, so the position inside the warm envelope matters more than the model's freeze rating.
Well grit
Water from the ground carries grit, and the inlet strainer catches it. On a well-fed unit the strainer needs cleaning often and a pre-filter ahead reduces the frequency. A clogged one makes the unit cut out.
Scale from the well
Hardness drives the descaling interval, and a private well's hardness is not on any published sheet. The first year of service tells you what this property needs; service valves fitted at installation make the job practical.
Propane
The unit draws a high input while firing. The tank, regulator and line have to carry that alongside the range, the furnace and anything else running.
Where it belongs
A barn wash bay, a tack room, a guest unit: a small heater at the building beats a long run that cools and freezes.
What survives a repair
Filters, sensors, igniters, boards. Not the coil.