Water heater maintenance is unglamorous and mostly about removing things: sediment from the tank, load from the lining, doubt from the safety devices. Done on a sensible interval, it is the cheapest way to get a tank to the end of its expected life.
Flushing
Draining the tank through its own valve and refilling until the water runs clear is the entire procedure. What comes out is the mineral layer that settles from heated water onto the tank floor and the elements.
Left in place, that layer slows heat transfer and holds moisture against the steel, and the popping sound owners report is water boiling underneath it. A tank carrying years of deposit may need its drain valve checked before the job starts, because a valve that will not close again leaves the situation worse than never opening it.
The anode rod
Every glass-lined tank carries a rod of magnesium or aluminium that gives up its own metal so the steel does not. Checking it is the only way to know how much protection is left.
On a tank still holding water and pressure, swapping a consumed rod buys years. Where corrosion has already reached the lining, the same swap buys very little, and saying so plainly is part of an honest visit.
The relief valve
The temperature and pressure relief valve is a safety device. It should not discharge in normal operation, and it should not be capped or plugged under any circumstances. Testing it, and replacing one that is stuck, weeping or scaled shut, is the most important item on the list.
Water from the relief discharge pipe is a fault signal. The cause is thermal expansion, excessive pressure or a failed valve, and each needs a different response.
Venting and combustion
On a gas unit, the flue and draft hood are checked for corrosion, blockage and clearance. A blocked flue is a carbon monoxide risk, not an efficiency issue, and it is checked every visit for that reason.
What maintenance will not do
A failed element stays failed, a cracked shell stays cracked, and a unit too small for the house stays too small. Maintenance protects what is still sound; it does not rebuild what is not. When the symptom is no hot water rather than slow recovery, start with the repair page instead.
Setting an interval
Age, water hardness, household size and whether the unit runs a recirculation loop all shift the right interval. A maintenance visit is also the natural moment to look at the shut-off valve and the drain pan, because those are the parts that decide how bad the next leak is.