A maintenance call on a well-fed tank follows a fixed order, and the order is the point. Drain, inspect, test, then look at the space around the unit before anything is closed up.
Draining
The tank is emptied through its own valve and refilled until the water runs clean. What comes out is the only honest measure of how much grit the well is sending, and it sets the interval for next time. A filter upstream reduces the load, but it does not remove the need for this.
The rod
Inside a glass-lined tank, a magnesium or aluminium rod is there to corrode instead of the steel. Nobody can tell how much is left without pulling it out and looking, and renewing one on a healthy tank is money well spent. On a tank that has already begun to corrode, it buys much less.
The safety valve
A relief valve stuck shut is a pressure vessel with no release. It is lifted and checked at every visit, and any water from its discharge sends us looking for the reason rather than reaching for a cap.
Cold weather
Before the first frost, exposed pipework is lagged, any trace heating is tested, and the space around the unit is measured for how cold it falls. An exchanger holding water through a hard freeze is the most expensive outcome available here.
The flame
Soot on a gas appliance is a message about combustion. The burner and flue are checked and the flame is read rather than assumed.
Where maintenance ends
Components can be renewed; a split vessel cannot. When hot water has stopped entirely, start with the repair page; when the tank has failed, replacement is the answer.